Specializing in Canine and Feline Neurology and Neurosurgery for Over 30 Years

General Library

 

0-9   A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

protozoa

Simplest type of organism in the animal kingdom; unicellular eukaryotic (have nucleus) organisms that range in size from submicroscopic to macroscopic; most are free-living but many are parasitic. 

Related Words

parasite

proximal

Toward the point of attachment or origin.

 


psychomotor seizure

See complex seizure.

Related Words
complex partial seizure

ptosis

Drooping of the upper eyelid often from paralysis of the oculomotor nerve or from sympathetic innervation.

Related Words

innervation ; oculomotor nerve ; paralysis ; sympathetic division


pug dog encephalitis (PDE)

Breed specific immune-mediated disease causing severe inflammation of the brain.

►click here to learn more-link provided by: www.petplace.com 

Related Words

brain  ;  immune-mediated disease  ;  inflammation

pulse oximeter

Purpose:  Instrument used to measure the arterial oxygen saturation of hemoglobin and pulse rate.  Oxygen saturation is the average amount of oxygen bound to each hemoblobin molecule.  Each erythrocyte (red blood cell) contains millions of hemoglobin molecules and one molecule of hemoglobin can carry up to 4 molecules of oxygen (which is then 100% saturated with oxygen).  This is an indicator of how well the cardio-respiratory system is working together to get oxygen delivered to all parts of the body.  

How Works:  Shines two different wavelengths of light (red and infrared) through a thin piece of tissue, e.g. tongue.  The absorption of light at the different wavelengths by hemoglobin differs depending on the degree of oxygenation of hemoglobin.  The percentage saturation is given as a digital readout together with an audible signal varying in pitch depending on oxygen saturation.  The light signal following transmission through the tissues has a pulsatile component, resulting from the expansion and contraction of the arterial blood vessels with each heartbeat.  This can be distinguished by the microprocessor from the non-pulsatile component resulting from venous, capillary and tissue light absorption.  Where flow is sluggish (e.g. hypovolemia or vasoconstriction) the pulse oximeter may be unable to function.

Example of Uses:  Detect hypoxia before a patient becomes clinically cyanotic.  


pupillary light response (PLR)

Contraction of the pupil on exposure of the retina to light; dependent on proper functioning of the optic and oculomotor nerves.

Related Words

oculomotor nerve  ;  optic nerve  ;  retina

pus

A whitish or yellowish, viscous liquid, inflammatory product composed of leukocytes (i.e. white blood cells) and fluid.  An accumulation of pus in an enclosed space is called an abscess.

Related Words
abscess  ;  inflammation

quadriplegia

See tetraplegia.

Related Words

tetraplegia

rabies

Infectious disease of the central nervous system caused by a virus from the family Rhabdoviridae; classified as an RNA virus because its genetic material is composed of ribonucleic acid (RNA).

►click here to learn more-link provided by: www.merckvetmanual.com 

Related Words

acute ; central nervous system (CNS) ; disease ; infection ; virus



Display #